Generator equipment configuration expert tailored emergency power distribution scheme

Causes of poor heat generation of Dongguan generator sets

人气:: Article Source: Popularity :: Issuing time: 2018-10-29 16:56:00
Causes of poor heat generation of Dongguan generator sets:
(1) The pump is malfunctioning. Check whether the pump works well. If it is found that the transmission gear shaft wear exceeds the limit, it indicates that the pump has failed to function and needs to be replaced to circulate normally.
(2) The radiator fins are blocked or damaged. The cooling fan does not work or the cooling fins are blocked, so that the temperature of the cooling liquid cannot be lowered, the cooling fins are rusted, causing liquid leakage and poor circulation.
(3) The thermostat is faulty. A thermostat is installed in the engine combustion chamber to control the temperature of the combustion chamber of the Dongguan generator . The thermostat must be fully opened at the specified temperature (82 degrees) to facilitate small circulation. If there is no thermostat, the coolant cannot maintain the circulation temperature. A low temperature alarm may occur.
(4) The level of coolant of the generator set is too low or does not meet the requirements. If the liquid level is too low, the coolant temperature will rise directly and the coolant will not circulate. The coolant is required to be 50% antifreeze and 50% demineralized water DCA4. If it does not meet the requirements, it will cause pipeline blockage and rust on the pipe wall. To prevent the coolant from circulating properly.
(V) Air is mixed in the cooling system of the Dongguan generator set, which causes the pipeline to be blocked. Damage to the suction valve and exhaust valve on the expansion tank also directly affects the circulation. At this time, it should always be checked whether their pressure value meets the regulations. The air pressure is 10kpa and the exhaust pressure is 40kpa. In addition to the times, whether the exhaust pipeline is unblocked is also an important reason affecting the circulation. http://ftfan.cn/